<?xml version='1.0' encoding='UTF-8' standalone='yes' ?>
|
|
<!--
|
|
This file can provide additional camera calibration settings beyond those built into the SDK itself.
|
|
Each calibration is for a particular camera (indicated by USB vid & pid pair) and a particular
|
|
capture resolution for the camera. Note: it is very important when capturing images used to calibrate
|
|
a camera that the image acquisition tool can actually control this capture resolution within the camera
|
|
itself and that you use this setting correctly. Many image acquistion tools do not in fact provide
|
|
this level of control.
|
|
|
|
Beyond simply providing additional, new camera calibrations, calibrations provided herein can
|
|
*replace/update* those that are builtin to the SDK. This matching is keyed, of course, by the
|
|
(vid, pid, size) triple. Further, if such a calibration has the 'remove' attribute with value 'true',
|
|
any existing calibration with that key is removed (and the calibration itself not added).
|
|
|
|
Calibrations are internally processed according to aspect ratio. If a format is requested in a size
|
|
that is not calibrated, but a calibration does exist for the same aspect ratio on the same camera,
|
|
then the latter will be scaled to accommodate the request. For example, if a 640x480 calibration
|
|
is requested but only a 800x600 calibration exists for that camera, then the 800x600 is scaled
|
|
down to service the 640x480 request.
|
|
|
|
Further, it is important to note that if *no* calibrations exist for a given camera, then Vuforia
|
|
is offered the entire range of capture resolutions that the hardware can support (and it does its
|
|
best to deal with the lack of calibration). However, if *any* calibrations are provided for a camera,
|
|
then capture resolutions in those aspect ratios supported by the camera for which any calibrations
|
|
are *not* provided are *not* offered. Thus, if you calibrate a camera but fail to calibrate all
|
|
the camera's supported aspect ratios, you limit the choices of capture resolutions that Vuforia can
|
|
select from.
|
|
|
|
One image acquisition program that supports control of camera capture resolution is YouCam 7:
|
|
https://www.cyberlink.com/products/youcam/features_en_US.html
|
|
|
|
Programs that can process acquired images to determine camera calibration settings include:
|
|
https://www.3dflow.net/3df-zephyr-free/ (see "Utilities/Images/Launch Camera Calibration" therein)
|
|
http://graphics.cs.msu.ru/en/node/909
|
|
Note that the type of images that must be acquired in order to calibrate is specific to the
|
|
calibration software used.
|
|
|
|
The required contents are illustrated here by example. Note that for the attribute names, both the
|
|
camelCase or the underscore_variations are supported; they are equivalent. The attributes for
|
|
each Calibration are as follows:
|
|
|
|
size (int pair): space separated camera resolution (width, height).
|
|
focalLength (float pair): space separated focal length value.
|
|
principalPoint (float pair): space separated principal point values (width, height).
|
|
distortionCoefficients (an 8-element float array): distortion coefficients in the following form
|
|
(r:radial, t:tangential): [r0, r1, t0, t1, r2, r3, r4, r5]
|
|
see https://docs.opencv.org/2.4/modules/calib3d/doc/camera_calibration_and_3d_reconstruction.html
|
|
|
|
The examples here are commented out as the values are built-in to the FTC SDK. They serve instead
|
|
here as examples on how make your own.
|
|
|
|
-->
|
|
<Calibrations>
|
|
|
|
<!-- ======================================================================================= -->
|
|
|
|
<!-- Microsoft Lifecam HD 3000 v1, Calibrated by PTC using unknown tooling -->
|
|
<!-- <Camera vid="Microsoft" pid="0x0779">
|
|
<Calibration
|
|
size="640 480"
|
|
focalLength="678.154f, 678.17f"
|
|
principalPoint="318.135f, 228.374f"
|
|
distortionCoefficients="0.154576f, -1.19143f, 0f, 0f, 2.06105f, 0f, 0f, 0f"
|
|
/>
|
|
</Camera> -->
|
|
|
|
<!-- ======================================================================================= -->
|
|
|
|
<!-- Microsoft Lifecam HD 3000 v2, Calibrated by PTC using unknown tooling -->
|
|
<!-- <Camera vid="Microsoft" pid="0x0810">
|
|
<Calibration
|
|
size="640 480"
|
|
focalLength="678.154f, 678.17f"
|
|
principalPoint="318.135f, 228.374f"
|
|
distortionCoefficients="0.154576f, -1.19143f, 0f, 0f, 2.06105f, 0f, 0f, 0f"
|
|
/>
|
|
</Camera> -->
|
|
|
|
<!-- ======================================================================================= -->
|
|
|
|
<!-- Logitech HD Webcam C310, Calibrated by by Robert Atkinson, 2018.05.30 using 3DF Zephyr -->
|
|
<!-- <Camera vid="Logitech" pid="0x081B">
|
|
<Calibration
|
|
size="640 480"
|
|
focalLength="821.993f, 821.993f"
|
|
principalPoint="330.489f, 248.997f"
|
|
distortionCoefficients="-0.018522, 1.03979, 0, 0, -3.3171, 0, 0, 0"
|
|
/>
|
|
|
|
<Calibration
|
|
size="640 360"
|
|
focalLength="715.307f, 715.307f"
|
|
principalPoint="319.759f, 188.917f"
|
|
distortionCoefficients="-0.0258948, 1.06258, 0, 0, -3.40245, 0, 0, 0"
|
|
/>
|
|
</Camera> -->
|
|
|
|
<!-- ======================================================================================= -->
|
|
|
|
<!-- Logitech HD Pro Webcam C920, Calibrated by Robert Atkinson, 2018.05.30 using 3DF Zephyr -->
|
|
<!-- <Camera vid="Logitech" pid="0x082D">
|
|
|
|
<Calibration
|
|
size="640 480"
|
|
focalLength="622.001f, 622.001f"
|
|
principalPoint="319.803f, 241.251f"
|
|
distortionCoefficients="0.1208, -0.261599, 0, 0, 0.10308, 0, 0, 0"
|
|
/>
|
|
|
|
<Calibration
|
|
size="800 600"
|
|
focalLength="775.79f, 775.79f"
|
|
principalPoint="400.898f, 300.79f"
|
|
distortionCoefficients="0.112507, -0.272067, 0, 0, 0.15775, 0, 0, 0"
|
|
/>
|
|
|
|
<Calibration
|
|
size="640 360"
|
|
focalLength="463.566f, 463.566f"
|
|
principalPoint="316.402f, 176.412f"
|
|
distortionCoefficients="0.111626 , -0.255626, 0, 0, 0.107992, 0, 0, 0"
|
|
/>
|
|
|
|
<Calibration
|
|
size="1920, 1080"
|
|
focalLength="1385.92f , 1385.92f"
|
|
principalPoint="951.982f , 534.084f"
|
|
distortionCoefficients="0.117627, -0.248549, 0, 0, 0.107441, 0, 0, 0"
|
|
/>
|
|
|
|
<Calibration
|
|
size="800, 448"
|
|
focalLength="578.272f , 578.272f"
|
|
principalPoint="402.145f , 221.506f"
|
|
distortionCoefficients="0.12175, -0.251652 , 0, 0, 0.112142, 0, 0, 0"
|
|
/>
|
|
|
|
<Calibration
|
|
size="864, 480"
|
|
focalLength="626.909f , 626.909f"
|
|
principalPoint="426.007f , 236.834f"
|
|
distortionCoefficients="0.120988, -0.253336 , 0, 0, 0.102445, 0, 0, 0"
|
|
/>
|
|
|
|
</Camera> -->
|
|
|
|
<!-- ======================================================================================= -->
|
|
|
|
<!-- Logitech HD Webcam C270, Calibrated by Noah Andrews, 2019.03.13 using 3DF Zephyr -->
|
|
<!--<Camera vid="Logitech" pid="0x0825">
|
|
<Calibration
|
|
size="640 480"
|
|
focalLength="822.317f, 822.317f"
|
|
principalPoint="319.495f, 242.502f"
|
|
distortionCoefficients="-0.0449369, 1.17277, 0, 0, -3.63244, 0, 0, 0"
|
|
/>
|
|
</Camera> -->
|
|
|
|
<!-- ======================================================================================= -->
|
|
|
|
</Calibrations>
|